CARRIER 50PCH PDF

Find out more about our 50PCH / PCV (kW) products on the Carrier UK website. grammed, easy to use, Carrier Comfort Controller set up for a WSHP . through panel opposite air coil on back discharge units. 50PCH. UNIT. SIZE. OVERALL. Find great deals for Carrier Aquazone 4 Ton 50pch Compact Water Source Heat Pump /60/3. Shop with confidence on eBay!.

Author: Jujind Dojind
Country: Samoa
Language: English (Spanish)
Genre: Spiritual
Published (Last): 20 January 2004
Pages: 13
PDF File Size: 4.61 Mb
ePub File Size: 3.76 Mb
ISBN: 376-1-49907-521-2
Downloads: 98550
Price: Free* [*Free Regsitration Required]
Uploader: Sarisar

These kits include heavy duty steel brackets and rubber grommets for sound and vibration isolation from the building structure. Condensate overflow sensor is an electronic sensor mounted to the drain pan.

Studies have also shown that these air coil coatings improve moisture shedding and therefore improve a units 50;ch removal capability resulting in a more comfortable indoor environment. The WSHP Open controller has its own hardware clock that is automatically set when the heat pump software is downloaded to the board.

Carrier Aquazone 50pch Indoor Water-cooled Heat Pump 50PCH042ZCC5ACN1 3.5 Ton

Two-Position Water Valve — Carfier two-position motorized water valve is optional on all unit sizes and is a great energy savings option. Side to Back Discharge Conversion 1. Water characteristics such as pH value, alkalinity, hardness, and specific conductance are important when considering any WSHP application. Filtered for maximum velocity of 6 fps. Easy removal of the control box from the unit provides access to all refrigeration components.

  HAYWOOD AND NAHMAD PDF

Step 6 – Install Condensate Drain. Al- low 15 minutes carrler cooling and heating tests for pressure to equalize. If units with these arrangements are not used, the contractor supplying the water source heat pumps is responsible for any extra costs incurred by other trades and must submit detailed mechanical drawings showing ductwork requirements and changes or relocation of any other mechanical 50cph electrical system. The units shall have an insulated divider panel between the air handling section and the compressor section to minimize the transmission of compressor noise, and to permit service testing without air bypass.

Compact cabinet dimensions fit tight space limitations in both horizontal and vertical configurations.

Water problems fall into three main categories: Step 3 – Locate Unit. Air coil freeze protection check filter operation provides a field selectable switch for assessing excessive filter pressure drop. Extended range for units operating with entering water temperatures below dew point. Lift the discharge panel from side of unit and cartier it to back using care not to damage blower wiring.

Carrier Aquazone Ton 50pch Compact Water Source Heat Pump /60/1 | eBay

The valve is factory set to open when the evaporating pressure falls to 90 psi and will modulate to prevent the pressure falling any 8 lower. Optional tin electro-plated copper tubing with high-tech polymer coated aluminum fins protect the evaporator coil from all forms of corrosive elements in the airstream. A light emitting diode LED shall annunciate the following alarms: Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.

  BLLHOFF HELICOIL PDF

Thermostat wiring Check Y and W wiring at heat pump. Corrosion is also common in salt-water areas. Balance airflow at registers. This constant torque motor is similar in function to a PSC, but can handle up to 1 in.

As a rule of thumb, size the water seal 1 in. Insulation within the air handling section shall not have any exposed edges.

Copyright Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without carrjer and without incurring obligations. Interpolation is permissible; extrapolation is not.

Consult the water quality guidelines for proper application and selection of this option. Single-stage water source heat pumps with puron refrigerant ra 68 pages. Step 7 – Pipe Connections. Units shall be supplied completely factory built and capable of operation with an entering water temperature range from 50 to F. Evaporator coil protection — Optional tin electroplated copper tubing with high-tech polymer coated aluminum fins will protect the evaporator coil from all forms of corrosive elements in the airstream.

Based upon F direct well, 85 F indirect well HX. To print the manual completely, please, download it.